Description
BUY NE558N https://www.utsource.net/itm/p/12382666.html
| Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
| Supply Voltage |
Vcc |
4.5 |
- |
16 |
V |
| Quiescent Current (per timer) |
Iq |
3 |
5 |
10 |
mA |
| Output Current (Sink) |
IOL |
200 |
- |
- |
mA |
| Output Current (Source) |
IOH |
- |
- |
100 |
mA |
| Output Voltage (Low) |
VOL |
0.25 |
0.4 |
0.75 |
V |
| Output Voltage (High) |
VOH |
3.3 |
- |
Vcc-1.5 |
V |
| Trigger Input Voltage |
Vtr |
1/3Vcc |
- |
2/3Vcc |
V |
| Threshold Input Voltage |
Vth |
2/3Vcc |
- |
- |
V |
| Reset Input Voltage |
Vr |
0.7 |
- |
Vcc |
V |
| Temperature Range |
T |
-40 |
- |
85 |
°C |
Instructions for NE558N:
Power Supply:
- Connect the supply voltage (Vcc) to pin 14 and ground (GND) to pin 7.
- Ensure the supply voltage is within the range of 4.5V to 16V.
Trigger Input (Pin 2):
- Apply a low pulse (less than 1/3 Vcc) to trigger the timer.
- Use a capacitor and resistor in series to create a timing circuit.
Threshold Input (Pin 6):
- Connect the threshold input to the same capacitor as the trigger input to control the timing.
- The threshold voltage should be set to 2/3 Vcc for proper operation.
Discharge Pin (Pin 7):
- This pin is used to discharge the timing capacitor.
- It can be connected directly to the capacitor to ground.
Reset Input (Pin 4):
- Apply a high signal (greater than 0.7V) to reset the timer.
- If not used, connect it to Vcc to prevent accidental resets.
Control Voltage (Pin 5):
- This pin can be used to adjust the threshold and trigger levels.
- If not used, connect it to ground through a 10nF capacitor to stabilize the internal comparator.
Output (Pin 3):
- The output can sink up to 200mA and source up to 100mA.
- Use external transistors or drivers for higher current applications.
Operating Temperature:
- Ensure the device operates within the temperature range of -40°C to 85°C.
Layout Considerations:
- Keep the power supply lines short and use decoupling capacitors (e.g., 100nF) close to the Vcc and GND pins to reduce noise.
Testing:
- Test the NE558N by applying a trigger pulse and measuring the output waveform with an oscilloscope to ensure correct timing and functionality.
(For reference only)
More detail about Utsource Holding Company Limited