Adaptive circulation for variable building demand.
Secondary chilled water pump systems are designed to distribute chilled water from a primary loop to the building's terminal units (AHUs, FCUs, fan coils), dynamically adjusting flow to match real-time cooling needs. EKG Malaysia specializes in the design, installation, and optimization of these systems, ensuring efficient, stable, and responsive cooling across all zones.
Core Function:
Decoupled Operation: Hydraulically separated from the primary loop via a common pipe, allowing independent flow control.
Variable Flow, Variable Speed: Pumps are equipped with Variable Frequency Drives (VFDs) and respond to differential pressure (ΔP) sensors to maintain system pressure while reducing flow (and energy) during part-load conditions.
Key System Components:
Secondary Pumps: Typically variable speed, sized for building distribution losses.
Common Pipe (Decoupler): A short bridge between primary and secondary loops that allows flow independence.
Differential Pressure (ΔP) Sensors: Installed in critical locations to provide feedback for pump speed control.
Control Valves: 2-way valves at terminal units modulate to control cooling; closed valves signal the system to reduce flow.
Why Use a Secondary System?
Chiller Protection: Keeps flow through chillers constant, as required by most designs.
Pump Energy Savings: Secondary pumps slow down significantly at part load, reducing energy use by 30–50% or more.
Improved Control & Comfort: Provides stable pressure for proper control valve operation across all zones.
Design Flexibility: Easier to zone and expand the building system independently of the chiller plant.
Critical Design & Balancing Considerations:
Correct Common Pipe Sizing: To prevent unwanted flow "short-circuiting" or reverse flow.
ΔP Sensor Location: Critical for representing the "worst-case" pressure drop in the system.
System Balancing: Ensuring design flow to all terminal units under all operating conditions.
Our Secondary System Services:
Design & Retrofit Planning: Converting constant flow systems or designing new installations.
Pump Selection & Control Strategy: Sizing pumps and programming VFDs for optimal response.
Commissioning & Balancing: Precisely setting flows and validating decoupler operation.
Performance Optimization: Tuning control sequences and pressure setpoints for maximum savings.
Optimize distribution, maximize savings.
A well-designed secondary system is key to an efficient, modern chilled water plant.