HVAC T&C Contractor

分类: Testing & Commissioning (T&C) for New AHUs 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

Finding a specialized HVAC Testing & Commissioning (T&C) Contractor in 2026 requires more than just mechanical labor; you need a partner who understands the strict statutory landscape of the Energy Efficiency and Conservation Act (EECA) 2024. In Malaysia, especially for projects in Kuala Lumpur and Selangor, T&C is the legal bridge between a completed installation and a building's occupancy permit.

At EKG (Malaysia) SDN BHD, we act as your technical auditors. We ensure that every VFD-driven AHU, chiller, and duct network performs exactly to design while satisfying BOMBA (JBPM) and Suruhanjaya Tenaga (ST) standards.


1. Statutory Compliance & 2026 Standards

As a professional T&C contractor, our primary goal is to ensure your facility passes its mandatory audits.


2. Our Core T&C Service Modules

We utilize NATA-traceable, calibrated instruments to provide an "Audit-Proof" technical report.

Service Module Engineering Action 2026 Target
Airflow Traverse Multi-point Pitot tube measurement in ducts. ±10% of Design Airflow
ESP Verification Measuring Static Pressure across the system. Optimized for minimal fan energy.
AC System Balancing Proportional balancing of terminal outlets. Elimination of "Hot Spots" and noise.
Hydronic Balancing Chilled water flow and Delta T verification. High $\Delta T$ ($5.5^\circ\text+$ ) for chiller COP.
Acoustic Audit Octave band analysis of room noise. NC 30 - 35 in office zones.

3. Advanced Engineering Diagnostics

We go beyond simple checksheets by using diagnostic technology to optimize your Building Energy Intensity (BEI).

  1. DALT (Duct Air Leakage Test): We verify that your ducting meets SMACNA Seal Class A. Leakage in unconditioned spaces is a direct violation of 2026 energy codes.

  2. Psychrometric Mapping: we verify the AHU Air-Side Heat Transfer. This ensures the cooling coil is effectively removing the 90% humidity prevalent in Malaysia without over-cooling the space.

  3. VFD Logic Stress Testing: We calibrate the VFD Integrated Static Pressure Transducer to ensure the fan correctly "ramps down" during partial occupancy (e.g., lunch hours or night shifts).


4. Why Partner with EKG (Malaysia) SDN BHD?

Is your HVAC system documented and ready for its 2026 statutory energy and fire audit?

Contact EKG (Malaysia) SDN BHD today for a professional HVAC T&C Contractor to ensure your project is compliant, efficient, and ready for operation.

Would you like us to review your current BMS Control Logic to ensure it meets the 2026 static pressure reset requirements?

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD