AHU Ducting & Terminal Connection Setup: AHU Outlet Fitting

In the 2026 Malaysian engineering sector, the AHU Outlet Fitting is a critical aerodynamic transition that connects the high-velocity discharge of the Air Handling Unit to the main supply ductwork. Governed by MS 1525:2024 and the Energy Efficiency and Conservation Act (EECA) 2024, this fitting is the primary point where "System Effect" losses occur. A poorly designed outlet fitting can increase static pressure by as much as 30%, forcing the VFD to run at higher frequencies and violating statutory Specific Fan Power (SFP) limits.

At EKG (Malaysia) SDN BHD, our outlet fittings are engineered to be Sterile, Silent, and Statutory-Compliant, ensuring the most efficient energy transfer from the fan to the building.


1. The Engineering Challenge: "System Effect"

When air leaves the fan discharge, it is highly turbulent and has a non-uniform velocity profile. If the outlet fitting is too abrupt, the air cannot "settle," leading to massive pressure drops.


2. Statutory Standards: EECA 2024 & SFP

Under the 2026 enforcement rules, every AHU must meet the 1.6 kW/m³/s SFP limit. The outlet fitting is a major factor in this calculation.

Fitting Type Pressure Drop (Typical) Impact on BEI Rating
Abrupt Transition 45 - 60 Pa High; likely to push the building into a lower Star rating.
Radius-Guided Fitting 10 - 15 Pa Low; contributes to a 4-star or 5-star Building Energy Intensity rating.
Vane-Integrated Transition 15 - 20 Pa Moderate; a compliant solution for tight plant rooms.

3. Core Components of a Professional Outlet Setup

A professional EKG installation utilizes a coordinated assembly at the AHU discharge:

  1. Flexible Connection: A double-flanged, fire-rated flexible connector is mandatory. It prevents the fan's mechanical vibration from being transmitted into the ductwork, ensuring the facility meets NC 30-35 acoustic standards.

  2. Transformation Piece: A customized "tapered" fitting that matches the square/rectangular fan discharge to the main supply duct size.

  3. Acoustic Lining: The first 3 to 5 meters of the outlet ductwork are typically internally lined with 50mm acoustic media to absorb the "Blast Noise" directly from the fan blades.

  4. Static Pressure Sensor: The VFD Integrated Static Pressure Transducer is often located just after the outlet fitting to provide the primary feedback loop for the VFD speed control.


4. The "Fire Mode" Statutory Protocol

The outlet fitting must maintain structural integrity during an emergency under BOMBA (JBPM) 2026 regulations.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU fighting high static pressure at the discharge point? Contact EKG (Malaysia) SDN BHD today for a specialized Outlet Aerodynamic & Statutory Compliance Audit.