AHU Airflow Test

Kategori: Testing & Commissioning (T&C) for New AHUs Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di eakon.com.my

Penerangan

Testing & Commissioning (T&C): AHU Airflow Test

In the 2026 Malaysian regulatory landscape, the AHU Airflow Test is the mechanical benchmark for compliance with the Energy Efficiency and Conservation Act (EECA) 2024. This test verifies that the AHU is delivering the design volume of air ($m^3/h$ or $L/s$) required to satisfy the thermal and latent loads of the building while remaining within the statutory Specific Fan Power (SFP) limit of 1.6 kW/m³/s.

At EKG (Malaysia) SDN BHD, our airflow testing protocols are Statutory-Compliant and Data-Driven, providing the empirical evidence needed for your Registered Energy Manager (REM) and BOMBA submissions.


1. The Statutory Mandate: EECA 2024 & BEI

Under current 2026 enforcement, the Airflow Test is no longer optional; it is a prerequisite for building occupancy and energy intensity (BEI) certification.


2. The EKG Airflow Testing Protocol

We utilize the Duct Traverse Method, which is the most accurate engineering approach for measuring total system volume.

Step 1: Duct Traverse Measurement

We drill small test holes in the main supply duct (typically in a straight run to ensure laminar flow). We then use a Pitot Tube or Hot-Wire Anemometer to take a grid of readings across the duct's cross-section.

Step 2: Velocity-to-Volume Conversion

The average velocity ($V_{avg}$) is multiplied by the cross-sectional area ($A$) of the duct to determine the Total Airflow ($Q$):

$$Q = V_{avg} \times A$$

Step 3: VFD Performance Mapping

We test the airflow at various VFD (Variable Frequency Drive) increments (e.g., 30Hz, 40Hz, 50Hz). This creates a "System Curve" that proves the VFD Integrated Static Pressure Transducer is correctly modulating the fan to save energy during partial loads.


3. Engineering for "Laminar Integrity"

The accuracy of an airflow test depends entirely on the quality of the Ducting Installation.


4. The "Fire Mode" Statutory Witness Test

The Airflow Test includes a mandatory high-velocity check to satisfy BOMBA (JBPM) 2026 safety standards.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU delivering the correct airflow to meet 2026 energy and health standards?

Contact EKG (Malaysia) SDN BHD today for a professional T&C: AHU Airflow Test.