Schneider Electric PowerLogic PM5000 Series
PowerLogic PM5000 Series Power & Energy Meters
Schneider Electric PowerLogic PM5000 Series meters are cost-effective power and energy meters for LV and MV electrical monitoring applications. The range supports panel metering, sub-metering, demand monitoring, basic power quality visibility, alarming, data logging and system integration.
The PM5000 family includes PM5100, PM5300, PM5500, PM5600 and PM5700 series models, with options for RS485, Ethernet, Class 0.5S or Class 0.2S energy accuracy, digital I/O, relay outputs and harmonic visibility.
PM5100 / PM5300 / PM5500 / PM5600 / PM5700
Class 0.5S / 0.2S Accuracy
RS485 / Ethernet
THD / TDD / Harmonics
Demand Monitoring
IoTWatt 4.0 Ready
Product Overview
The PowerLogic PM5000 Series is designed for electrical distribution monitoring, energy visibility and basic power quality analysis. It helps facility, energy and electrical teams monitor current, voltage, power, power factor, energy, demand, unbalance, harmonics, alarms and historical logs depending on the selected model.
The range is suitable for main incomers, sub-main feeders, MCC panels, distribution boards, tenant metering, utility metering points, production areas and critical electrical loads.
Positioning: PM5000 is ideal for practical multi-function metering, sub-metering, demand management, power factor review, harmonic visibility and IoTWatt 4.0 integration.
Why PM5000 Matters
PM5000 gives site teams better visibility than basic panel meters, without moving into a high-end power quality platform.
- Energy monitoring
- Sub-metering
- Demand profile
- Power factor review
- Harmonic visibility
- Alarm logs
- EMS integration
Typical Monitoring Architecture
PM5000 meters are installed at electrical panels and communicate through RS485 or Ethernet, depending on the model. Meter data can be collected by EMS, BMS, SCADA, EcoStruxure Power Monitoring Expert, IoTWatt 4.0 or other Modbus-based systems.
1
CT / Voltage Inputs
Panel or feeder measurement point.
2
PM5000 Meter
Electrical and energy measurement.
3
RS485 / Ethernet
Modbus communication to system.
4
Meter Data + Alarms
Trends, events and alerts.
5
EMS / BMS / IoTWatt
Dashboards, reports and analytics.
Key Features at a Glance
Multi-Function Metering
Measures voltage, current, power, power factor, frequency, energy and demand values.
Class 0.5S / 0.2S Accuracy
PM5100 / PM5300 support Class 0.5S, while PM5500 / PM5600 / PM5700 support Class 0.2S active energy accuracy.
Power Quality Visibility
Supports THD, TDD and individual harmonic visibility depending on selected model.
Demand Monitoring
Tracks present, last, predicted and peak demand values for load management.
Alarms and Logs
Supports setpoint alarms, digital alarms, event logs and timestamped data depending on model.
Digital I/O and Relay Options
Available digital inputs, digital outputs and relay outputs for pulse, status and alarm functions.
RS485 and Ethernet Models
Select RS485 Modbus or Ethernet-enabled models depending on the site architecture.
Sub-Metering Ready
Useful for tenant metering, department metering, process metering and feeder energy allocation.
IoTWatt 4.0 Ready
Meter data can support dashboards, alarms, analytics, EECA reports and digital energy audits.
PM5000 Series Model Positioning
| Series |
Typical Positioning |
Accuracy |
Harmonic Visibility |
Communication / I/O Notes |
| PM5100 Series |
Basic multi-function panel metering. |
Class 0.5S active energy. |
Up to 15th harmonic for selected models. |
Pulse or RS485 model options depending on reference. |
| PM5300 Series |
Enhanced metering with stronger logging, I/O and 31st harmonic visibility. |
Class 0.5S active energy. |
Up to 31st harmonic. |
RS485 or Ethernet models; 2DI / 2DO; relay models available. |
| PM5500 / PM5600 / PM5700 Series |
Higher-accuracy advanced power monitoring for important feeders and main metering points. |
Class 0.2S active energy. |
Up to 63rd harmonic. |
RS485 and Ethernet models; larger memory; 4DI / 2DO for selected models. |
| PM5563 |
DIN rail advanced meter for compact metering cabinets and no-display installations. |
Class 0.2S active energy. |
Up to 63rd harmonic. |
DIN mount, no display, RS485 and Ethernet. |
Power Quality and Network Visibility
PM5000 meters provide practical power quality visibility for electrical networks. Depending on model, the meters support total harmonic distortion, total demand distortion, individual harmonics, unbalance, min/max readings, demand values, alarm logs and event logs.
| Power Quality Function |
Purpose |
Typical Benefit |
| THD / thd |
Monitors voltage and current harmonic distortion. |
Helps identify distortion from VSDs, UPS systems, rectifiers and nonlinear loads. |
| Individual Harmonics |
Provides harmonic order visibility up to 15th, 31st or 63rd depending on model. |
Supports troubleshooting of harmonic sources and affected equipment. |
| TDD |
Tracks total demand distortion for current distortion review. |
Useful for electrical quality and harmonic review workflows. |
| Unbalance |
Monitors voltage and current unbalance. |
Helps detect phase loading issues that may affect motors, transformers and panels. |
| Min / Max with Timestamp |
Records when important parameters reach minimum and maximum values. |
Supports maintenance, load review and troubleshooting. |
| Alarms |
Setpoint and digital alarms notify abnormal electrical conditions. |
Improves operating visibility and response to network issues. |
Applications and Best-Fit Sites
- Main incomer monitoring
- Sub-metering
- Tenant metering
- Department metering
- Production line monitoring
- MCC panels
- Distribution boards
- Demand management
- Power factor review
- Harmonic review
- WAGES pulse monitoring
- EMS / BMS / SCADA
- IoTWatt 4.0
- EECA reporting support
Typical Measured Parameters
| Parameter Group |
Typical Measurements |
| Voltage |
Phase-to-phase, phase-to-neutral and average voltage values depending on wiring configuration. |
| Current |
Phase current, average current and neutral / ground current monitoring on selected models. |
| Power |
Active, reactive and apparent power, total and per phase, including signed four-quadrant measurement. |
| Energy |
Active, reactive and apparent energy, received / delivered, net / absolute and time counters. |
| Power Factor |
True power factor and displacement power factor, total and per phase. |
| Demand |
Present, last, predicted and peak demand with date and time stamping. |
| Power Quality |
THD, TDD, harmonics, unbalance and selected PQ functions depending on model. |
| Logs and Alarms |
Min / max log, data logging, maintenance log, alarm log and event log depending on model. |
Model Selection Guide
| Requirement |
Recommended PM5000 Direction |
| Basic power and energy monitoring |
PM5100 / PM5110 type models. |
| RS485 Modbus integration |
Select RS485-enabled PM5000 models such as PM5110, PM5310, PM5330 or PM5560. |
| Ethernet integration |
Select Ethernet-enabled models such as PM5320, PM5340, PM5560 or PM5563. |
| Cost allocation with better accuracy |
Use Class 0.5S or Class 0.2S models depending on metering importance. |
| Higher-accuracy important feeders |
Use PM5500 / PM5600 / PM5700 family models with Class 0.2S active energy accuracy. |
| Harmonic visibility |
Use PM5300 for up to 31st harmonic or PM5500 / PM5600 / PM5700 family for up to 63rd harmonic. |
| DIN rail installation |
Use PM5563 or other DIN-mount references where panel-front display is not required. |
| Local relay output functions |
Select PM5330 / PM5340 type models where relay output is required. |
Integration with IoTWatt 4.0
IoTWatt 4.0 can collect PM5000 meter data through RS485 Modbus, Ethernet Modbus TCP or a suitable gateway depending on the selected model. The collected data can support continuous energy monitoring, digital energy audit, EECA reporting, demand analytics and savings verification.
- kWh and kW monitoring
- Voltage and current trends
- Power factor review
- Demand analytics
- Harmonic dashboards
- Abnormal load detection
- Energy baseline support
- Sub-metering dashboards
- EECA reporting support
- Digital energy audit data
Integration note: RS485 PM5000 models can be connected through compatible gateways such as RS2LAN, RS2MQTT or RS2WLAN. Ethernet-enabled PM5000 models can be connected through the site LAN where network access is available.
Recommended Deployment Checklist
- Confirm metering objective
- Confirm accuracy class
- Confirm RS485 / Ethernet requirement
- Confirm harmonic visibility
- Confirm panel or DIN mounting
- Confirm CT ratio and class
- Confirm voltage wiring
- Confirm control power
- Confirm I/O or relay requirement
- Confirm WAGES pulse inputs
- Confirm EMS / BMS / SCADA integration
- Confirm IoTWatt 4.0 integration
- Test CT polarity
- Test communication and logs
PowerLogic PM5000 Supply, Commissioning and IoTWatt 4.0 Integration