Description
PyroCool Industrial Cabinet Air Conditioner
PyroCool HPC1500T Cabinet Air Conditioner
The PyroCool HPC1500T is a 1500W industrial cabinet air conditioner designed for cooling electrical control cabinets, automation panels, telecom cabinets, outdoor enclosures and equipment cabinets with concentrated internal heat sources.
The HPC Series uses closed-loop cabinet cooling to protect electrical and electronic equipment from high temperature, dust and humidity. It is suitable for indoor and outdoor cabinets where stable enclosure temperature is required for reliable equipment operation.
Cooling Capacity 1500W / 5100 BTU
Protection IP55 closed-loop cabinet cooling
Power Supply 220VAC, 50Hz
Control & Interface Digital thermostat, RS485 and dry contact alarm
Product Overview
Industrial control cabinets normally contain PLCs, drives, power supplies, communication equipment, relays and electronic components that generate heat. When this heat is trapped inside the cabinet, component life and system reliability can be affected.
The HPC1500T solves cabinet heating problems by providing dedicated closed-loop cooling with short internal air paths and uniform cooling air distribution. This helps maintain the cabinet internal temperature while separating the cabinet air from the external environment.
Positioning: 1500W industrial cabinet air conditioner for electrical enclosures, automation panels, outdoor cabinets and heat-sensitive control equipment.
Key Features
Indoor / Outdoor Cabinet Cooling
Suitable for both indoor and outdoor cabinet cooling applications.
Closed-Loop Protection
Protects internal cabinet equipment from heat, dust and humidity by separating internal and external air paths.
IP55 Protection
Designed for electrical enclosure cooling where cabinet protection and environmental separation are important.
Digital Display Thermostat
Provides local temperature control and setpoint visibility for cabinet cooling operation.
RS485 Communication
RS485 interface allows monitoring or integration into control / monitoring systems where required.
Dry Contact Alarm
Dry contact alarm output with NO / NC option supports remote alarm signalling to PLC, BMS or monitoring systems.
Industrial Components
Compressor supplied by Hitachi and fan supplied by EBM Papst according to the product brochure.
R134a Refrigerant
Uses R134a refrigerant for the cabinet air-conditioning circuit.
Corrosion Resistant Finish
Electrostatic coating in RAL7035 for a clean industrial cabinet finish.
Typical Applications
Electrical Control Panels
Cooling for PLC, relay, control power and instrumentation cabinets.
Automation Cabinets
Suitable for automation panels with drives, controllers, I/O modules and communication equipment.
Telecom Cabinets
Protect communication electronics and network equipment in indoor or outdoor enclosures.
Outdoor Enclosures
Useful for cabinets exposed to high ambient temperature, dust and humidity.
Industrial MCC / DB Rooms
Cooling for local cabinets where internal electrical heat needs to be removed.
IoT / Energy Monitoring Panels
Suitable for protecting gateways, meters, controllers and industrial networking devices.
Technical Specifications — HPC1500T
| Parameter |
HPC1500T Specification |
| Product Name |
1500W AC Cabinet Air Conditioner |
| Product Type |
AC Air Conditioner |
| Model Number |
HPC1500T |
| Cooling Capacity |
1500W / 5100 BTU |
| Power Supply |
220VAC, 50Hz |
| Power Consumption |
560W |
| Operating Temperature Range |
-40°C to +55°C |
| Running Current |
2.5A |
| Dimension |
L450 × D200 × H750mm |
| Dimension with Flange |
L484 × D200 × H784mm |
| Refrigerant |
R134a |
| IP Level |
IP55 |
| Noise Level |
65dB |
| Weight |
28kg |
| Installation |
Door mounted / face mounted |
| Certification |
CE |
| Colour |
Electrostatic coating, RAL7035 |
| Temperature Control Mode |
Digital display thermostat |
| Power Supply Connection |
Three-core conductor, 2–5m long |
Package Details
| Item |
HPC1500T Package Information |
| Standard Package |
Foam corner protector + individual carton |
| Optional Package |
Extra wooden case |
| Net Weight |
28kg |
| Gross Weight |
31kg |
| Single Carton Size |
L561 × D257 × H860mm |
| Extra Case |
Size and weight varies according to quantity in one case |
Installation and Mounting
The HPC1500T is designed for door-mounted or face-mounted installation on an electrical cabinet. The air conditioner is mounted through a cabinet cut-out with seal ring and mounting screws. The attached installation drawing shows the cabinet door, seal ring, air conditioner body and mounting screw arrangement.
| Mounting Detail |
HPC1500T Reference |
| Mounting Type |
Door mounted / face mounted |
| Flange Dimension |
484 × 784mm including flange |
| Mounting Hole |
24 × Ø6 mounting holes shown in product drawing |
| Installation Components |
Air conditioner body, seal ring, cabinet door and mounting screws |
| Drainage |
Drainage points shown in the product drawing |
Installation note: Confirm cabinet cut-out, cable entry, drainage, ventilation clearance and service access before installation. The cabinet door must be mechanically suitable for the air conditioner weight and mounting hole arrangement.
Why Use Closed-Loop Cabinet Cooling?
Fans and filtered ventilation can bring outside air, dust and humidity into the cabinet. Closed-loop cabinet air conditioning keeps the internal cabinet air separated from the external environment while removing heat from inside the enclosure.
- Protects PLCs, VFDs, drives, power supplies and electronics from high cabinet temperature.
- Reduces dust and humidity exposure compared with open ventilation cooling.
- Improves reliability of control and communication equipment in hot environments.
- Useful for outdoor cabinets where ambient conditions are harsh.
- Supports stable cabinet temperature for automation and monitoring systems.
- Helps reduce unplanned downtime due to heat-related component failure.
Recommended Selection Process
Correct sizing of a cabinet air conditioner depends on internal heat load, cabinet size, ambient temperature, target internal temperature and installation environment.
- Calculate total internal heat load from drives, power supplies, controllers, relays and other installed equipment.
- Confirm outdoor or indoor installation condition and maximum ambient temperature.
- Confirm required cabinet internal set temperature.
- Check cabinet size, insulation, solar exposure and heat gain from surroundings.
- Confirm IP rating requirement and whether closed-loop cooling is required.
- Confirm door strength, cut-out size and available mounting area.
- Confirm power supply, alarm wiring, RS485 communication and monitoring requirement.
Integration with IoTWatt 4.0 and Monitoring Systems
The HPC1500T includes RS485 communication and dry contact alarm output, making it suitable for integration into cabinet monitoring systems, PLCs, BMS, EMS or IoTWatt 4.0. Cabinet cooling status and alarm conditions can be used to improve maintenance response and protect critical equipment.
- Connect dry contact alarm to PLC, remote I/O or monitoring gateway.
- Use RS485 communication where supported for temperature and status monitoring.
- Monitor cabinet temperature together with equipment power and operating data.
- Create alarms or maintenance tickets when cabinet temperature rises or cooling fault occurs.
- Use IoTWatt 4.0 to correlate cabinet temperature, power consumption and equipment operation.
PyroCool HPC1500T Supply and Integration
Saturn Pyro supports PyroCool HPC1500T cabinet air conditioners for electrical control panels, automation cabinets, telecom enclosures, outdoor equipment cabinets, monitoring panels and industrial cabinet cooling projects in Malaysia.
Enquire Now