※In hysteresis output mode, detection difference is variable.
Applicable fluid
(Fluid type) Air, Non-corrosive gas and fluid that will not corrode Stainless steel 316L
Pressure port direction
Bottom fitting
Pressure port
NPT1/8
Connection type
Connector type(connector type cable: 2m)
Pressure type
Compound pressure
Rated pressure range
-101.3 to 100.0kPa
Display pressure unit
kPa, kgf/cm², bar, psi, mmHg, inHg, mmH₂O
Control output_NPN open collector
NPN open collector
Option input/output
Voltage(1-5VDC
) output
Power supply
12-24VDC
±10%(ripple P-P: max. 10%)
Current consumption
Voltage output type: Max. 50mA
Current output type: Max. 75mA
Protection structure
IP40
Control output_Hysteresis
Min. display interval
Control output_Repeat error
±0.2% F.S. ±Min. display interval
Control output_Response time
Selectable 2.5ms, 5ms, 100ms, 500ms, 1000ms
Environment_Ambient temperature
-10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity
30 to 80% RH, storage: 30 to 80% RH
Material
Front case: Polycarbonate, Rear case: Polyamide 6, Pressure port: SUS304/SUS316L
Weight
Approx. 173g(approx. 88g)
※It is allowed to select one analog output type only.
※The weight includes packaging. The weight in parenthesis is for unit only.
※F.S: Rated pressure.
※There may be ±1-digit error in hysteresis by pressure unit calculation error.
※The temperature or humidity mentioned in Environment indicates a non freezing or condensation.