| Model | NXO-2-T1(T2) | NXO-3-T1(T2) | |
| Circulation | forced hot-air circulation with 4" exhaust outlet | ||
| Power Source | AC 220V 3 Ø 60/50 Hz | ||
| Consumption Power | 6(T1).9(T2) KVA | 7.5(T1).10(T2) KVA | |
| Performance | Temperature Range | T1 : 60 ~ 250°C ; T2 : 60 ~ 350°C | |
| Temperature Stability | ± 0.5 °C | ||
| Temperature Uniformity |
± 1 °C at 100 °C ± 4 °C at 300 °C ± 2 °C at 200 °C ± 5 °C at 350 °C ± 3 °C at 250 °C |
||
| Warm - Up Time |
ambient temp. to 250 °C 35min ambient temp. to 350 °C 60min |
||
| Material | Interior Material | SUS 304# mirror finish stainless steel | |
| Exterior Material | SS 41# steel with baked paint | ||
| Heater | Ni-Cr alloy | ||
| Insulation | 48K mineral Wool | ||
| Inert Gas Lead-in- Device | i) Leakage In-Gas | N2, CO2 (normal gaseous) | |
| ii) Gas Preasure | input end Max. 10kg/cm2G; output end with pressure adjusting device | ||
| iii) Flow Volume | max. 25/min. (at max flow volume) | ||
| iv) Chamber Gauge | 3m/m Hg (at max. flow volume). | ||
| v) Duct | brass; heat resistance up to 180°C | ||
| vi) Pressure Guage | floating type | ||
| vii) Release Valve | action at pressure 0.5kg/cm2 | ||
| Oxygen Containing Volume | Below 22PPM when finish inflation | ||
| Safety Devices | i) Leakage Circuit Breaker | Protection for leakage; short circuit and over current. (sensitivity 30mA) | |
| ii) Fuse | rapid sensing with display; for heater and system protection. | ||
| iii) Blowing Motor Protection | over - current protection (settable type) | ||
| iv) over - Temp Prevention | H. alarm protection and liquid expansion type auxiliary protection. | ||
| v) Trouble display | separately display for every trouble | ||
| Dimension | Inside Dimensions (cm) | 60 x 60 x 60 | 65 x 50 x 90 |
| Outside Dimensions (cm) | 92 x 80 x 133(T1)/145(T2) | 92 x 70 x 162(T1)/174(T2) | |
| Interior Capacity | 216L | 270L | |
FEATURES:
Malaysia