Negative pressure HEPA modules

Negative pressure HEPA modules

分类: HEPA Filter Housing & Duct Modules 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

Negative Pressure HEPA Modules by EKG M&E Sdn Bhd

In 2026, Negative Pressure HEPA Modules are the critical infrastructure required for effective bio-containment and hazardous particulate control. Under the Energy Efficiency and Conservation Act (EECA) 2024 and updated DOSH biosafety protocols, these modules are mandatory for infectious disease isolation rooms, oncology compounding pharmacies, and high-hazard laboratories. For facilities in Kuala Lumpur and Selangor, maintaining a 5-Star BEI while ensuring 100% containment requires a module that balances high static pressure exhaust with precision-engineered airtightness.

At EKG M&E Sdn Bhd, we apply 34 years of mechanical engineering expertise to provide turnkey negative pressure HEPA solutions. We ensure your containment zone is hermetic, compliant with MS 1472, and optimized for a 5-Star Energy Intensity Label.


1. The Engineering Logic: The Containment Handshake

A negative pressure module works by exhausting more air than is supplied, creating a "Siphon Effect" that ensures air only flows into the hazardous zone, never out.


2. Specialized Containment Integration Protocols

To meet MOH (Ministry of Health), NPRA, and BOMBA 2026 standards, our negative pressure modules incorporate specific mechanical safeguards:

A. Bag-In Bag-Out (BIBO) Safe-Change

For high-potency or infectious environments, we utilize BIBO housings. This allows technicians to replace contaminated filters within a sealed PVC bagging system, ensuring that hazardous particulates are never released into the mechanical room or the surrounding environment during maintenance.

B. Integrated Validation Ports (PAO/DOP)

Every EKG negative pressure module includes integrated Aerosol Challenge and Sampling Ports. This allows for mandatory ISO 14644-3 filter integrity testing to be performed "in-situ." Technicians can verify the seal and media integrity while the room remains under negative pressure, ensuring continuous containment.

C. Pressure Cascade & Interlock Management

We integrate digital Differential Pressure Sensors linked to your Building Management System (BMS). The system maintains a constant negative gradient (typically $-15$ Pa to $-30$ Pa) relative to adjacent corridors. If the pressure fails, the module triggers an immediate interlock, shutting down supply fans to prevent the room from becoming "Positive" and leaking contaminants.


3. Compliance Matrix: Standard Exhaust vs. EKG Negative Pressure Module

Performance Metric Standard Exhaust Grille EKG Negative Pressure Module
Pathogen Retention None 99.995% (H14 HEPA)
Seal Type Friction Fit Gel-Seal / Knife-Edge (Hermetic)
Filter Replacement Open Exposure Bag-In Bag-Out (Zero-Exposure)
Testing Capability None Integrated Validation Ports
EECA 2024 Status Regulatory Risk Audit-Ready / 5-Star BEI Support

4. Why Professional Negative Pressure Modules are Essential for 2026

Why Choose EKG M&E Sdn Bhd?

Is your containment zone a potential bio-hazard risk, or is it a model of 5-star engineered safety? Contact EKG M&E Sdn Bhd today for specialized negative pressure HEPA modules and secure the future of your infrastructure.