AHU Sound Power Level (Lw) Verification

AHU Sound Power Level (Lw) Verification

分类: Testing & Commissioning (T&C) for New AHUs 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

Testing & Commissioning (T&C): AHU Sound Power Level ($L_w$) Verification

In the 2026 Malaysian corporate and industrial landscape, Sound Power Level ($L_w$) Verification is a critical T&C requirement for high-spec office environments, hospitals, and luxury residences. Under MS 1525:2024, noise control is no longer just a comfort metric; it is part of the building's statutory Indoor Environmental Quality (IEQ) audit. Failure to verify sound levels can result in non-compliance with the NC 30-35 (Noise Criteria) targets required for Grade-A building certification.

At EKG (Malaysia) SDN BHD, we perform $L_w$ verification to ensure your VFD-driven AHU operates with Acoustic Excellence, preventing mechanical "rumble" from disrupting workplace productivity.


1. The Engineering Principle: $L_w$ vs. $L_p$

It is critical to distinguish between these two metrics during a statutory audit:

Verification Goal: We verify the $L_w$ at the AHU discharge, inlet, and casing to ensure the manufacturer’s data matches the "As-Installed" reality.


2. Statutory Framework: MS 1525 & IEQ 2024

Under current 2026 enforcement, acoustic verification is a prerequisite for high-performance building ratings.

Acoustic Metric 2026 Statutory Target EKG Implementation
Noise Criteria (NC) NC 30 - 35 We verify $L_w$ to ensure the duct system can attenuate noise to these room levels.
Specific Fan Power 1.6 kW/m³/s Lower fan speeds (via VFD) naturally reduce $L_w$. We find the "Acoustic Sweet Spot."
Vibration Isolation 95% Efficiency We check spring isolators to ensure $L_w$ isn't converted into structural "hum."
GITA Eligibility IEQ Category Acoustic comfort documentation supports the "Indoor Quality" portion of Green Tax claims.

3. The EKG Acoustic Verification Protocol

Our mechanical specialists utilize Class-1 Sound Level Meters and Octave Band Analyzers to map the AHU’s acoustic signature.

  1. Octave Band Analysis: We measure noise across frequencies from 63Hz to 8,000Hz. High-frequency noise (whistling) usually indicates a leakage in the Zero-Leakage Snap-Lock Duct Collars, while low-frequency noise (rumble) indicates an issue with the IE5 EC Fan Wall.

  2. Casing Breakout Test: We measure the noise "breaking out" through the AHU panels into the plant room. This ensures the plant room's acoustic insulation is sufficient to protect adjacent office zones.

  3. VFD Frequency Sweep: We ramp the VFD through its operating range to identify "Resonant Frequencies"—specific speeds where the AHU might vibrate excessively. We then program the VFD to "skip" these frequencies for silent operation.


4. The "Fire Mode" Statutory Witness Test

Even during emergency operations, acoustic integrity must be monitored per BOMBA (JBPM) 2026 standards.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU system creating distracting noise or failing its acoustic audit?

Contact EKG (Malaysia) SDN BHD today for a professional AHU Sound Power Level ($L_w$) Verification & Statutory Audit.

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD