| Cartridge | 300 ml |
|
Unipack |
400 ml |
| Pail | 23 l |
| Drum | 195 l |
| Chemical Base |
1-component polyurethane
|
|
| Color (CQP001-1) |
Black, grey, white |
|
| Cure Mechanism |
Moisture-curing |
|
| Density (Uncured) |
depending on color |
1.3 kg/l |
| Non-Sag Properties |
Good |
|
| Application Temperature |
ambient |
5 ─ 35 °C
|
| Skin Time (CQP019-1) |
40 minutes A |
|
| Curing Speed (CQP049-1) |
(see diagram) |
|
| Shrinkage (CQP014-1) |
5 % |
|
| Shore A Hardness (CQP023-1 / ISO 48-4) |
40 |
|
| Tensile Strength (CQP036-1 / ISO 527) |
1.7 MPa |
|
| Elongation at Break (CQP036-1 / ISO 527) |
600 % |
|
| Tear Propagation Resistance (CQP045-1 / ISO 34) |
6 N/mm |
|
| Service Temperature (CQP513-1) | -50 ─ 90 °C | |
| Shelf Life |
12 months B |
|
CQP = Corporate Quality Procedure |
A) 23 °C / 50 % r. h. |
B) storage below 25 °C |
Surfaces must be clean, dry and free from grease, oil and dust.
Surface treatment depends on the specific nature of the substrates and is crucial for a long lasting bond. Suggestions for surface preparation may be found on the current edition of the appropriate Sika® Pre-Treatment Chart. Consider that these suggestions are based on experience and have in any case to be verified by tests on original substrates.
Sikaflex®-227 can be processed between 5 °C and 35 °C but changes in reactivity and application properties have to be considered. The optimum temperature for substrate and sealant is between 15 °C and 25 °C.
Sikaflex®-227 can be processed with manual, pneumatic or electric driven piston guns as well as pump equipment. For advice on selecting and setting up a suitable pump system, contact the System Engineering Department of Sika Industry.