| Measurement Parameters | MCCB Timing Tests, CT Turns Ratio, Protection Relay Delay Timing Test |
| Output Current | Up to 1000 A |
| Maximum Output Power | 1000 VA |
| Output Frequency | 40-70 Hz |
| Input Power | 100-240 V 47/63 Hz |
| Internal Meter Range | Up to 1000A; Accuracy: 0.5% |
| External Meter Range | 10 mA – 10 A; Accuracy: 0.5% |
| Timer Reading Range | 1ms – 2 hours; Accuracy: 0.1% of reading ±0.5ms |
| Timer Stop Input | Dry Contact Input, Voltage Input (Wet 12V) |
| Type | 5A-1000 A (Optional cable set required for 5A-32A current application) |
|
Memory
|
Up to 100 records, |
| Unlimited Storage using an external USB | |
| Communication | USB 2.0/1.1 Standard-A, USB 2.0/1.1 Standard-B |
| PC Software | DMP Software (Reporting) |
| Display | 4.3-inch colour touch display |
| Dimensions | (16.7 × 13.4 × 6.8)” (424 x 340 x 173) mm |
| Weight | 9 kg (device), 15 kg (Current Source) |
|
Temperature
|
Working: -10°C to +60°C |
| Storage: -30°C to +70°C | |
| Humidity | 95% RH Non-condensing |
| Safety | Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards |
| Protection | IP67 (case lid closed) |
|
Included in the package
|
1 KVA Transformer-Current Source (1 pcs), |
| 2.5m Measurement Cable (95 mm2) Set (4 pcs), | |
| Heavy duty Clamps for MCS-PICU Cable Set (2 pcs), | |
| 1.5m Booster Cable (between PICU & Transformer Source) (1 pcs), | |
| 5m Contact Cable (Blue) (1 pcs), | |
| 5m Contact Cable (White), (1 pcs), | |
| 5m Current Cable (Red), (1 pcs), | |
| 5m Current Cable (Black) (1 pcs), | |
| 1.8m Power Cord with Type F plug (1 pcs), | |
| 2.5m Hightest Standard Ground Cable (1 pcs), | |
| 1.8m USB Cable to connect Hightest devices with PCs | |
| USB Flash drive (Manual, Brochure) (1 pcs), | |
| Hard Carry Case for Accessories (1 pcs) | |
| Options | Hard Case, Cable Set for current application up to 32 A |
| Cable Size | Cable Length | Turn Number | Load | Current | Duration | Note |
|
95mm²
|
2.5m
|
1
|
SC
|
100A | 120 sec | Continuous |
| 500A | 120 sec | Continuous | ||||
| 560A | 60 sec | Max | ||||
|
2
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 900A | 20 sec | Max | ||||
|
3
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 1000A | 20 sec | Max | ||||
|
190mm² (2x95mm² Parallelly Connected)
|
2.5m
|
1
|
SC
|
100A | 120 sec | Continuous |
| 500A | 120 sec | Continuous | ||||
| 650A | 60 sec | Max | ||||
|
2
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 1000A | 60 sec | Max | ||||
|
285mm² (3x95mm² Parallelly Connected)
|
2.5m
|
1
|
SC
|
100A | 120 sec | Continuous |
| 500A | 120 sec | Continuous | ||||
| 750A | 60 sec | Max | ||||
|
2
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 1000A | 60 sec | Max | ||||
|
380mm² (4x95mm² Parallelly Connected)
|
2.5m
|
1
|
SC
|
100A | 120 sec | Continuous |
| 500A | 120 sec | Continuous | ||||
| 800A | 60 sec | Max | ||||
|
2
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 1000A | 60 sec | Max | ||||
|
95mm² (2×2.5m Serially Connected)
|
5m
|
1
|
SC
|
100A | 120 sec | Continuous |
| 350A | 120 sec | Max | ||||
|
2
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 600A | 60 sec | Max | ||||
|
3
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 600A | 60 sec | Max | ||||
|
4
|
100A | 120 sec | Continuous | |||
| 500A | 120 sec | Continuous | ||||
| 750A | 30 sec | Max | ||||
|
95mm² (4×2.5m Serially Connected)
|
10m
|
1
|
SC
|
100A | 120 sec | Continuous |
| 200A | 120 sec | Max | ||||
|
2
|
100A | 120 sec | Continuous | |||
| 350A | 60 sec | Max |