BOMBA Smoke Spill Duct Integrity Test

BOMBA Smoke Spill Duct Integrity Test

Category: Duct Leakage Testing (DW143 Standard) Available
For more information, visit our official website at eakon.com.my

Description

BOMBA Smoke Spill Duct Integrity Test by EKG M&E Sdn Bhd

In 2026, the Smoke Spill Duct Integrity Test is a non-negotiable legal requirement for high-occupancy and high-rise buildings in Malaysia. Under the Uniform Building By-Laws (UBBL) and MS 1780, smoke spill systems (Smoke Extract Systems) must be verified to effectively exhaust toxic gases during a fire. This test is the final hurdle to obtaining or renewing your BOMBA Fire Certificate (FC).

At EKG M&E Sdn Bhd, we apply 34 years of mechanical engineering expertise to ensure your fire-rated ductwork maintains its structural and airtight integrity under extreme heat, protecting lives and your building's compliance status.


1. The Core Engineering Mandate (BOMBA 2026)

A smoke spill system is only as good as its weakest joint. If a duct leaks or collapses during a fire, it fails to remove smoke from evacuation routes.


2. The Integrity Testing Procedure

We conduct a rigorous, multi-stage "Live" verification to prove the system performs as designed:

  1. Pressure Testing (DW143): We pressurize the fire-rated duct to its design operating pressure (often above ). This measures the air loss per square meter to ensure it meets the Class C airtightness limit.

  2. Smoke Performance Test: We use Non-Toxic Smoke Generators to visualize the airflow. This confirms that the smoke is being successfully extracted from the fire zone and discharged at the rooftop or external wall without leakage in between.

  3. Stability & Support Inspection: We verify that the duct supports (hangers) are fire-rated and spaced correctly. If supports fail under heat, the entire duct line could collapse, blocking fire paths.

  4. BMS Integration Check: We trigger the fire alarm signal to verify that the Motorized Smoke Dampers open and the Smoke Extract Fans ramp up to full speed within the required response time.


3. Compliance Matrix: Fire Duct vs. Standard Duct

Feature Standard HVAC Ducting EKG BOMBA-Certified Fire Duct
Fire Rating None 2-Hour (FRL 120/120/120)
Integrity Warps at < 200°C Maintains Shape up to 1000°C
Sealant Type Standard Silicone High-Expansion Intumescent
Testing Goal Comfort / Energy Life Safety / Smoke Containment
Audit Required Optional Maintenance Mandatory for Fire Certificate (FC)

4. Why This Matters for Your 2026 Audit

Why Choose EKG M&E Sdn Bhd?

Is your building's fire ducting ready for the 2026 BOMBA audit? Contact EKG M&E Sdn Bhd today for a professional smoke spill duct integrity test and secure your Fire Certificate renewal.