Engineered for gamma radiography on thinner materials, smaller components, and applications where moderate Ir-192 activity delivers optimal penetration and image quality. With Ir-192 capacity up to 50 Ci (1.85 TBq), the 880 Series Elite gamma-ray source projector provides dependable performance without the elevated radiation profile of higher-activity devices. It's the reliable choice when you need isotope versatility, global regulatory compliance, and consistent performance across diverse non-destructive testing (NDT) environments.
Positioned between the high-capacity 880 Series Delta and lower-capacity 880 Series Omega, the 880 Series Elite gamma camera delivers a balanced solution for use in field or plant settings.
QSA Global designed the 880 Series Elite to comply with ANSI N432-1980, ISO 3999:2004(E), IAEA TS-R-1 (2009), IAEA SSR-6 (2012), USNRC 10CFR34 and 10CFR71, and USDOT 49CFR173, ensuring safe, compliant operation worldwide.
| Ideal Use | Low-energy isotopes and lower Ir-192 activity |
| Max Source Activity | Ir-192: 50 Ci (1.85 TBq) Se-75: 150 Ci (5.55 TBq) Yb-169: 108 Ci (4.00 TBq) |
| Steel Thickness Range | Ir-192: 0.39–3.54 in (10–90 mm) Se-75: 0.20–1.57 in (5–40 mm) Yb-169: ≤ 0.79 in (≤ 20 mm) |
| Focal Size Options | Ir-192: as small as 0.071 in (1.80 mm) Se-75: as small as 0.039 in (1.0 mm) |
| Weight | 42 lb (19.0 kg) |
| Transport Package |