JM Surface Emergency Keluar Sign - TR218C [SIRIM]

JM Surface Emergency Keluar Sign - TR218C [SIRIM]

Kategorya: EMERGENCY KELUAR SIGN Magagamit
Para sa karagdagang impormasyon, bisitahin ang aming opisyal na website sa esllighting.com.my

Deskripsyon

JM Surface Emergency Keluar Sign TR218C

The JM Surface Emergency Keluar Sign (Model: TR218C) is a high-efficiency, BOMBA Approved emergency exit lighting solution engineered for commercial, industrial, and residential premises across Malaysia. Featuring an ultra-durable anodised aluminium housing, low-energy SMD LED lamps, and a certified 3+ hour battery backup, the TR218C guarantees full compliance with standard Malaysian Fire and Safety Regulations (MS983, MS619, MS IEC 60598-1). It is designed for seamless wall or ceiling mounting to maintain continuous visibility during emergency power outages.

Full Description:

Ensure your building complies with Malaysian safety codes with the JM Surface Emergency Keluar Sign - TR218C. Designed for heavy-duty commercial setups, retail outlets, factories, and high-rise developments, this surface-mounted exit light delivers bright, reliable illumination when you need it most.
 

Full Fire Department & Regulatory Compliance

Fire safety inspections require non-negotiable adherence to local laws. The JM TR218C carries full BOMBA Approval and complies with key Malaysian Standards:  
  • MS983:2004 – Emergency lighting performance standard.
  • MS619-2-22:2012 – Specific requirements for emergency lighting luminaires.
  • MS IEC 60598-1:2012 – Electrical safety for lighting fittings.

Energy-Efficient Maintained LED Operation

Operating on a Maintained mode, the sign remains continuously illuminated during normal mains electricity supply and automatically transitions to internal battery power during a blackout. Equipped with 16 × SMD LEDs (16 x 0.2W SMD LED in emergency mode), the light consumes less than 6.3VA, keeping electrical bills low while offering superior luminosity and uniform light output.  

Long-Lasting Battery Backup & Protection

Power outages are unpredictable, but your exit markers shouldn't be. The built-in Sealed Nickel-Cadmium (Ni-Cd) Battery guarantees a rated emergency operating duration exceeding 3 Hours. An integrated Low Voltage Cut-off safety feature automatically disconnects the battery before complete depletion, preventing over-discharge and extending overall battery lifespan. A front-facing Red LED Charging Monitor keeps facilities managers updated on the unit's charge state at a glance.  
 

Heavy-Duty Anodised Aluminium Casing

Built to withstand commercial wear and tear, the casing is constructed from high-grade Anodised Aluminium Extrusion. With an IP20 ingress protection rating, it offers strong defense against dust and debris while maintaining a modern, professional visual aesthetic.  
Specifications
  • Model: TR218C
  • Mode of Operation: Maintained
  • Input Voltage: 240V±10% 50Hz
  • Power Consumption: <6.3VA
  • Battery Type: Sealed Nickel-Cadmium Battery
  • Lamp Used: SMD LED
  • Lamp-Mains "ON": 16 × 0.2W SMD LED
  • Lamp-Main "OFF": 16 × 0.2W SMD LED
  • Rated Duration:>3 Hours
  • Housing: Andolised Aluminium Extrusion
  • Changing Monitor: Red LED Indicates Battery Charging
  • Projection Rating: IP20
  • Safety Feature: Low Voltage Cut-off to Prevent Over Discharge of the Battery
  • Mounting Type: Wall or Ceiling Mounting
  • Certified Compliance: MS983:2004 , MS619-2-22:2012 , MS IEC 60598-1:2012 , BOMBA APPROVED
  • Dimension Keluar: 538(L)mm × 198(W)mm × 125(H)mm
  • Outer Box: 578(L)mm × 43(W)mm × 245(H)mm
  • Inner Box: 555(L)mm × 40(W)mm × 235(H)mm
Q1: Is the JM TR218C Keluar Sign BOMBA approved in Malaysia?
A: Yes, the JM TR218C Emergency Keluar Sign is fully BOMBA approved and certified compliant with Malaysian Standards MS983:2004, MS619-2-22:2012, and MS IEC 60598-1:2012 for commercial premise safety regulations.

Q2: How long does the battery last during a power blackout?
A: The JM TR218C features a sealed Nickel-Cadmium battery that provides a rated backup duration of more than 3 hours during power failures.

Q3: What is the difference between Maintained and Non-Maintained emergency lights?
A:A Maintained emergency sign (like the TR218C) stays illuminated continuously during normal power supply and stays lit during a power outage. Non-Maintained lights only turn on when normal mains power fails.

Q4: Can the JM TR218C exit sign be mounted on both walls and ceilings?
A: Yes, the unit is designed for versatile surface-mounting applications and can be installed on either walls or ceilings.

Q5: What safety features prevent the battery from degrading quickly?
A: The sign incorporates an automatic Low Voltage Cut-Off circuit that disconnects the battery before it completely drains, shielding it from over-discharge damage.                

Q6: How  do I know if the JM TR218C is charging properly?        
A: The sign includes an integrated red LED indicator on the casing that illuminates to signal active battery charging.  

Q7: Does this exit sign consume a lot of electricity?  
A:No, the JM TR218C uses energy-efficient SMD LEDs with a very low power consumption rating of under 6.3VA.

Q8: What housing material is used for the JM TR218C fixture?
A:It is constructed with durable, corrosion-resistant Anodised Aluminium Extrusion, delivering a sleek finish and an IP20 protection rating.

Q9: Why is SIRIM and BOMBA certification critical for exit lights in Malaysia?
A:Non-certified emergency exit lights risk failing building fire safety audits, leading to severe legal fines, delayed business operations, or denied insurance claims during emergency incidents.

Tingnan ang karagdagang mga detalye tungkol sa E S L Lighting (M) Sdn Bhd
E S L Lighting (M) Sdn Bhd
E S L Lighting (M) Sdn Bhd LED Lighting Supplier Selangor, Lighting Shop Seri Kembangan, Kuala Lumpur (KL), Decorative Lighting Supplies Malaysia ~ E S L Lighting (M) Sdn Bhd