Duct static pressure sensor calibration

Duct static pressure sensor calibration

分类: Air Balancing and Comissioning 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

Duct Static Pressure Sensor Calibration by EKG M&E Sdn Bhd

In 2026, Duct Static Pressure Sensor Calibration is the foundational "digital truth" required for HVAC efficiency. Under the Energy Efficiency and Conservation Act (EECA) 2024, a system with uncalibrated sensors is considered an energy liability. If your static pressure sensor is off by just 25 Pascals (Pa), your Variable Frequency Drives (VFDs) may be over-speeding, leading to massive energy waste and failing your Suruhanjaya Tenaga (ST) audit.

At EKG M&E Sdn Bhd, we apply 34 years of mechanical engineering depth to synchronize your physical air pressure with your digital control logic, ensuring your building in Kuala Lumpur or Selangor maintains its 5-Star Energy Intensity Label.


1. The Engineering Impact of Sensor Drift

The static pressure sensor is the "brain" that tells the fan how hard to blow. In Malaysia's high-humidity environment, sensors often suffer from "drift" due to moisture, dust accumulation, or electronic aging.


2. The EKG Calibration Protocol

We use medical-grade, laboratory-calibrated instruments to perform a 3-point verification of your sensor network:

A. Physical Zeroing and Inspection

We ensure the sensor's reference port is open to a stable atmosphere (usually the mechanical room or outside) and that the sensing probe is placed in a non-turbulent section of the duct—typically two-thirds of the way down the longest run.

B. Parallel Reference Testing

Using a high-precision digital micromanometer, we take a physical reading at the exact same point as the sensor. We compare the "Physical Truth" of the manometer to the "Digital Readout" on your Building Management System (BMS).

C. K-Factor and Offset Adjustment

If a deviation is found (standard tolerance is within +/- 5%), we adjust the "Offset" or "Gain" (K-Factor) within the BMS software until the digital reading matches the physical measurement across three different fan speeds (33%, 66%, and 100%).


3. Compliance Matrix: Audit-Ready Sensor Data

Our calibration services provide the certified proof required for your Registered Energy Manager (REM):

Metric Uncalibrated (Legacy) EKG Calibrated (2026)
Reading Accuracy +/- 15% to 25% +/- 2% (Design Target)
VFD Response Erratic / Hunting Smooth / Load-Following
Energy Impact High Peak Demand Optimized BEI Performance
EECA Status Regulatory Risk Audit-Ready & Compliant
IAQ Safety Unverified Pressure Certified 500 cfu/m3 Barrier

4. Why Calibration is Essential for 2026

Why Choose EKG M&E Sdn Bhd?

Is your BMS accurately reflecting your building's mechanical performance? Contact EKG M&E Sdn Bhd today for professional duct static pressure sensor calibration and secure the 5-star efficiency of your building.