The two-electrode online conductivity sensor uses graphite as the test material,which has good test accuracy and stability.It uses RS485 communication interface,supports MODBUS protocol,and has a built-in high precision NTC sensor to perform accurate temperature compensation for conductivity measurement in real time.



|
Technical Data
|
|
|
Principle
|
Two-electrode graphite electrode method
|
|
Measured variables
|
Conductivity,Resistivity,TDS,Salinity
|
|
Measuring range
|
0-20000uS/cm
|
|
Measuring accuracy
|
≤±1%
|
|
Response time
|
≤15s
|
|
Temperature range
|
0-60℃
|
|
Temperature accuracy
|
≤±0.3℃
|
|
Working environment
|
0-40℃,5bar
|
|
Power supply
|
12-24V DC
|
|
Cable length
|
5 meters,OEM available
|
|
Power
|
0.5W
|
|
External interface
|
RS-485 MODBUS-RTU protocol
|
|
IP grade
|
IP 68
|
|
Main material
|
Graphite,epoxy,ABS,316 stainless steel
|
|
Installation
|
Flow cell installation,pipe installation,submersible installation
|
Malaysia