Description
BUY EE-SX1103 https://www.utsource.net/itm/p/9773978.html
| Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
| Operating Voltage |
Vcc |
2.0 |
3.3 |
5.5 |
V |
| Operating Current |
Icc |
- |
10 |
- |
μA |
| Sensing Distance |
S |
1.0 |
1.5 |
2.0 |
mm |
| Response Time |
Tr |
- |
1 |
- |
ms |
| Release Time |
Tf |
- |
1 |
- |
ms |
| Output Type |
- |
- |
NPN Open Collector |
- |
- |
| Maximum Load Current |
IOL |
- |
50 |
- |
mA |
| Maximum Output Voltage |
VOL |
- |
0.4 |
- |
V |
| Operating Temperature |
Topr |
-40 |
- |
85 |
°C |
| Storage Temperature |
Tstg |
-40 |
- |
125 |
°C |
Instructions for Use:
Power Supply:
- Connect the Vcc pin to the positive terminal of the power supply.
- Ensure the operating voltage is within the range of 2.0V to 5.5V.
Ground Connection:
- Connect the GND pin to the negative terminal of the power supply.
Output Connection:
- The output is an NPN open collector type. Connect the load between the output pin and the positive supply.
- Ensure the maximum load current does not exceed 50mA.
Sensing Distance:
- The sensor has a typical sensing distance of 1.5mm, with a range of 1.0mm to 2.0mm.
- Adjust the position of the sensor to achieve the desired detection range.
Response and Release Time:
- The response time (Tr) and release time (Tf) are both typically 1ms.
- These times may vary slightly depending on environmental conditions.
Temperature Considerations:
- The sensor can operate within a temperature range of -40°C to 85°C.
- Store the sensor in a temperature range of -40°C to 125°C.
Mounting:
- Mount the sensor in a stable position to avoid mechanical stress.
- Ensure there is no interference from nearby objects that could affect the sensing distance.
Wiring:
- Use appropriate wire gauges to minimize voltage drops and ensure reliable operation.
- Shield cables if used in noisy environments to prevent electromagnetic interference.
Maintenance:
- Regularly inspect the sensor for any signs of damage or wear.
- Clean the sensor surface if necessary to maintain optimal performance.
Safety:
- Do not exceed the maximum ratings specified in the table.
- Follow all relevant safety guidelines when handling and installing the sensor.
(For reference only)