Product Description
The Festo VAEM-S6 series AS interface modules are dedicated operating components for VTSA valve terminals, providing direct fieldbus communication between the pneumatic valve island and higher level control systems via AS Interface . These modules are available in two variants: VAEM-S6-S-FAS-4-4E (4 inputs/4 outputs) and VAEM-S6-S-FAS-8-8E (8 inputs/8 outputs), supporting up to 4 or 8 valve positions . With IP65 protection, CRC 0 corrosion resistance, and LABS conformity, the VAEM-S6 series ensures reliable and safe integration for demanding industrial automation applications .
Key Features & Advantages
AS Interface Fieldbus Communication: Provides direct connection to AS i networks via M12x1, 4 pin socket and plug connectors, enabling seamless data exchange with the host controller . The VAEM-S6-S-FAS-4-4E has ID1=Fh, ID2=Eh, IO code 7h, Profile S 7.A.7, while the VAEM-S6-S-FAS-8-8E has ID1=Fh, ID2=Eh
4 or 8 Inputs/Outputs: The 4 4E variant supports up to 4 solenoid coils and 4 inputs, handling 4 monostable or 2 bistable valve positions . The 8 8E variant supports up to 8 solenoid coils and 8 inputs, handling 8 monostable or 4 bistable valve positions
Comprehensive Device Specific Diagnostics: Provides diagnostics for short circuit/overload of inputs, undervoltage detection, and peripheral errors, enabling rapid fault detection and system troubleshooting
High Protection Class IP65: Achieves IP65 degree of protection in mounted state, providing dust tight protection and protection against water jets, suitable for harsh industrial environments
No Corrosion Stress (CRC 0): Rated CRC 0 according to FN 940070, ensuring exceptional durability even in demanding applications with no corrosion risk
LABS (PWIS) Conformity VDMA24364-B1/B2-L: Complies with paint wetting impairment substances standards, making these modules suitable for paint shop environments and applications sensitive to paint defects
Galvanic Isolation via Optocoupler: The fieldbus interface is galvanically isolated using an optocoupler, protecting the module from electrical interference and ground loops
Wide Operating Voltage Range: AS Interface DC operating voltage range from 26.5 V to 31.6 V, with load voltage range from 21.6 V to 26.4 V DC, ensuring compatibility with standard AS i power supplies
Addressing Range 1 31 (0): Addressing set using an AS Interface addressing device, with DIL switch control elements for configuration
Positive Switching Logic (PNP): Input switching logic is PNP (positive switching), compatible with standard industrial sensors and controllers
LED Status Indication: Bus specific LEDs indicate AS i mode, AS i power supply (Aux/Pwr), and AS i fault status . Product specific LEDs (0 7) show switching status of inputs, while LEDs 12/14 show switching status of pneumatic valves (on the valve itself)
Wide Operating Temperature Range: Operates reliably from -5°C to 50°C ambient temperature, with storage temperature from -20°C to 60°C and relative humidity up to 90% non condensing
Robust PA Housing with NBR/PUR Seals: Manufactured from PA (polyamide) housing material with NBR and PUR seals, offering excellent durability and chemical resistance
Reverse Polarity Protection: Includes reverse polarity protection for all electrical operating voltage connections, safeguarding the module from incorrect wiring
CE and RoHS Certified: Meets EU EMC Directive, EU Low Voltage Directive, and RoHS environmental standards
Compatible with VTSA Valve Terminals: Specifically designed for integration with VTSA valve islands, providing a complete pneumatic and electrical automation solution
Technical Specifications
Brand: Festo
Model Series: VAEM-S6
Product Numbers: 549044 (VAEM-S6-S-FAS-4-4E), 549045 (VAEM-S6-S-FAS-8-8E)
Product Type: AS Interface Module / Operating Component
Series: VAEM-S6
Application: VTSA valve terminals
Fieldbus Protocol: AS Interface
VAEM-S6-S-FAS-4-4E (549044):
Max. solenoid coils: 4
Max. inputs/outputs: 4 / 4
Max. valve positions: 4 (monostable) or 2 (bistable)
Number of slaves per device: 1
Product identification: ID1=Fh, ID2=Eh, IO code 7h, Profile S 7.A.7
Weight: 300 g
VAEM-S6-S-FAS-8-8E (549045):
Max. solenoid coils: 8
Max. inputs/outputs: 8 / 8
Max. valve positions: 8 (monostable) or 4 (bistable)
Number of slaves per device: 2
Product identification: ID1=Fh, ID2=Eh
Weight: 300 g
Common Technical Data:
Fieldbus interface: Socket M12x1, 4 pin / Plug M12x1, 4 pin
Device specific diagnostics: Short circuit/overload of inputs, Undervoltage, Via peripheral error
Mounting position: Any
Reverse polarity protection: For all electrical operating voltage connections
Control elements: DIL switch
AS Interface DC operating voltage range: 26.5 V to 31.6 V
Load voltage range DC: 21.6 V to 26.4 V
Load voltage supply: Via load voltage connection (24 V DC)
Nominal operating voltage DC AS Interface: 26.5 V
Nominal voltage DC: 24 V
AS Interface residual ripple: ≤ 20 mVss
Load voltage residual ripple: 4 Vss
Switching level: Signal 0 ≤ 5 V, Signal 1 ≥ 11 V
Permissible voltage fluctuations: ±10%
CE marking: As per EU EMC Directive, EU Low Voltage Directive
Corrosion resistance class (CRC): 0 – No corrosion stress
LABS (PWIS) conformity: VDMA24364-B1/B2-L
Storage temperature: -20°C to 60°C
Relative air humidity: 0% to 90%
Degree of protection: IP65 (in mounted state)
Ambient temperature: -5°C to 50°C
Electrical actuation: Fieldbus
Input switching logic: PNP (positive switching)
Electrical connection: Via CPX
Addressing range: 1 to 31 (0), setting using AS Interface addressing device
Galvanic isolation fieldbus interface: Optocoupler
LED display (bus specific): AS i, Aux/Pwr, Fault
LED display (product specific): 0 7 (input status), 12/14 (valve status on pneumatic valve)
Seals material: NBR, PUR
Housing material: PA
Material note: RoHS compliant
Country of Origin: Germany
Ideal For
VTSA valve terminal AS Interface communication and control, industrial automation systems requiring IP65 protection for harsh environments, applications needing integrated I/O at the valve terminal (4 or 8 inputs/outputs), paint shop environments requiring LABS conformity (VDMA24364-B1/B2-L), systems requiring CRC 0 no corrosion stress for demanding applications, and distributed valve terminal control via AS i networks.
Why Choose Festo VAEM-S6 Series Operating Component
Choose the Festo VAEM-S6 series AS Interface module for its dedicated role as the communication gateway for VTSA valve terminals, available in two variants to match your I/O requirements: VAEM-S6-S-FAS-4-4E (4 coils, 4 I/O, 4 monostable/2 bistable valve positions) and VAEM-S6-S-FAS-8-8E (8 coils, 8 I/O, 8 monostable/4 bistable valve positions). Featuring AS Interface fieldbus communication via M12x1, 4 pin connectors, device specific diagnostics for short circuit/overload, undervoltage, and peripheral errors, IP65 degree of protection for dust tight and water jet resistance, CRC 0 corrosion resistance for demanding applications, LABS conformity (VDMA24364-B1/B2-L) for paint shop environments, galvanic isolation via optocoupler for electrical protection, wide AS i operating voltage range (26.5 31.6 V) and load voltage range (21.6 26.4 V), addressing range 1 31 with DIL switch control elements, positive switching logic (PNP), comprehensive LED status indicators for bus and product status, wide -5°C to 50°C operating temperature range, robust PA housing with NBR/PUR seals, reverse polarity protection for all electrical connections, CE and RoHS certifications, and German engineering quality. This operating component series delivers reliable, flexible, and safe AS i fieldbus integration for demanding VTSA valve terminal applications.
Tags
#Festo #VAEMS6 #OperatingComponent #VTSA #ASInterface #Fieldbus #ValveTerminal #549044 #549045 #IP65 #CRC0 #LABSConformant #M12Connector #8Inputs #8Outputs #PneumaticControl #IndustrialAutomation #MalaysiaSupplier
More detail about GREX IND SUPPLY
Malaysia