详情
CIRCUTOR Compact Panel-Mounted Power Analyzer
CVM-C4-ITF-485-ICT2 Power Analyzer
The CIRCUTOR CVM-C4 is a compact 96 x 96 mm panel-mounted power analyzer designed
to measure, calculate and display the main electrical parameters of single-phase and
three-phase electrical networks, with or without neutral.
The CVM-C4-ITF-485-ICT2 model supports true RMS measurement, indirect current
measurement through .../5 A or .../1 A current transformers, RS-485 Modbus RTU
communication, relay outputs, digital inputs and transistor pulse outputs.
96 x 96 mm Panel Mount
Only 41.5 mm Depth
RS-485 Modbus RTU
True RMS Measurement
4-Quadrant Measurement
THD% Visibility
2 Relay Outputs
2 Digital Inputs
Model
CVM-C4-ITF-485-ICT2
Product Code
M52706
Communication
RS-485, Modbus RTU
Current Input
.../5 A or .../1 A CT input
Product Overview
CVM-C4 is suitable for electrical panels where installation space is limited but essential
measurement, local display and remote communication are required. With a depth of only
41.5 mm, it is useful for compact switchboards, retrofit panels, distribution boards,
MCC panels and machine control panels.
The analyzer measures instantaneous electrical values, active and reactive energy, voltage
and current THD%, and supports four-quadrant measurement. It can be used for consumed
or generated energy logging and for monitoring energy from two different sources using
digital input activation.
Key positioning
CVM-C4 is a compact multifunction power analyzer for low-voltage electrical panels,
SCADA / EMS / BMS integration, energy metering, alarm output and basic harmonic visibility.
Key Features
96
Compact Panel Mounting
96 x 96 mm front size with only 41.5 mm depth for space-saving panel installation.
RMS
True RMS Measurement
Measures main electrical parameters using 3 AC voltage inputs and 3 current inputs.
485
RS-485 Modbus RTU
Supports remote readout and integration with SCADA, EMS, BMS and master systems.
4Q
Four-Quadrant Measurement
Supports consumed and generated energy measurement for modern electrical installations.
THD
Harmonic Visibility
Displays voltage and current THD% to support basic power quality checking.
DI
Digital Inputs
2 potential-free digital inputs for source, tariff or dual energy metering applications.
RO
Relay Alarm Outputs
2 relay outputs allow local operation when programmed alarm conditions are triggered.
S0
Pulse Outputs
2 passive transistor outputs for energy impulse applications up to 5000 imp/kWh.
CT
Indirect Current Measurement
Designed for external .../5 A or .../1 A current transformers.
Typical Monitoring Architecture
CVM-C4 measures the electrical installation locally and sends values via RS-485 Modbus RTU
to a gateway, PLC, SCADA, BMS, EMS or IoTWatt 4.0 platform.
1. Electrical Panel
Voltage inputs and external CTs.
2. CVM-C4
Local measurement, display and I/O.
3. RS-485 Network
Modbus RTU communication.
4. Gateway / SCADA
Data collection and integration.
5. IoTWatt 4.0
Dashboards, alarms and audit reports.
Typical Applications
Electrical Panels
For compact LV panels, MCC panels, DB panels and retrofit switchboard monitoring.
Energy Metering
Measures consumed or generated active and reactive energy for local or remote use.
Remote Monitoring
RS-485 Modbus RTU enables connection to SCADA, EMS, BMS and IoT gateways.
Alarm Monitoring
Relay outputs can be programmed with activation time, delay and hysteresis.
Tariff / Source Separation
Digital inputs support energy measurement from two different sources or tariffs.
IoTWatt 4.0 Integration
Use as a compact Modbus field meter for dashboards, EECA reporting and energy audit workflows.
Product Identification
| Parameter |
Value |
| Product Family |
CVM-C4 |
| Model |
CVM-C4-ITF-485-ICT2 |
| Code |
M52706 |
| Product Type |
Power analyzer / multifunctional multimeter for panel |
| Mounting |
Panel mounted, 96 x 96 mm |
| Protocol |
Modbus RTU |
| Communication |
RS-485 |
| Input Current |
.../5 A or .../1 A using external current transformers |
Technical Specifications
| Item |
Specification |
| Dimensions |
96 x 96 x 41.5 mm |
| Weight |
0.268 kg |
| Enclosure |
Polycarbonate + ABS |
| Protection Class |
Front IP54, rear IP20 |
| AC Power Supply |
80 to 270 Vac, 50 / 60 Hz, 6 to 18 VA |
| DC Power Supply |
80 to 270 Vdc, 1.5 to 1.8 W |
| Installation Category |
CAT III 300 V |
| Operating Temperature |
-10°C to +60°C |
| Storage Temperature |
-20°C to +70°C |
| Relative Humidity |
5% to 95%, without condensation |
Measurement and Accuracy
| Measurement |
Specification |
| Voltage Inputs |
3 AC voltage inputs |
| Current Inputs |
3 current channels, 1 A / 5 A AC nominal current |
| Voltage Range |
100 to 277 V phase-neutral, ±8% |
| Frequency Range |
45 to 65 Hz |
| Current Overload |
1.2 In continuous, 10 In instantaneous for 5 seconds |
| Phase Voltage Accuracy |
0.2% |
| Phase Current Accuracy |
0.2% |
| Active / Reactive Power Accuracy |
0.5% |
| Active / Reactive Energy Accuracy |
0.5% |
| Power Factor Accuracy |
0.5% |
Communication and I/O
| Function |
Specification |
| Communication Interface |
RS-485 |
| Protocol |
Modbus RTU |
| Baud Rate |
2400 / 4800 / 9600 / 19200 bps |
| Data Bits |
8 |
| Stop Bits |
1 or 2 |
| Parity |
None / Even / Odd |
| Digital Inputs |
2 potential-free contacts, 3.75 kV RMS insulation |
| Relay Outputs |
2 relay outputs, 250 Vac / 5 Aac or 30 Vdc / 5 Adc resistive load |
| Transistor Outputs |
2 passive impulse outputs, 10 Hz maximum frequency, 27 mA maximum current |
Dimensions and Connection Overview
Dimensions
Panel mounting and dimension reference for the CVM-C4 compact power analyzer.
Connection Diagram
Connection reference for voltage inputs, current inputs, auxiliary supply, RS-485 and I/O terminals.
Installation note
The CVM-C4 is intended for panel mounting and indirect current measurement using external
.../5 A or .../1 A current transformers. CT ratio, CT polarity and voltage wiring should be
checked and configured correctly before commissioning.
Standards and Compliance References
- IEC 61010-1.
- IEC 61000-4-2.
- IEC 61000-4-3.
- IEC 61000-4-4.
- IEC 61000-4-5.
- IEC 61000-4-6.
- IEC 61000-4-8.
- IEC 61000-4-11.
Integration with IoTWatt 4.0
CVM-C4 can be integrated into IoTWatt 4.0 through RS-485 Modbus RTU using an industrial
gateway. This makes it suitable for compact panel monitoring, energy dashboards, alarms,
EECA reporting support and digital energy audit workflows.
| IoTWatt 4.0 Use |
How CVM-C4 Supports It |
| Energy Dashboard |
Provides electrical and energy parameters from compact electrical panels. |
| Digital Energy Audit |
Supports load profile, consumption and operating pattern visibility. |
| Alarm Monitoring |
Relay outputs and measured values support local or platform-based alarm strategy. |
| Power Quality Visibility |
THD% values help flag possible harmonic issues for further investigation. |
| Retrofit Projects |
Small depth and RS-485 Modbus communication make it suitable for retrofit panels. |
Recommended Selection and Deployment Checklist
- Confirm network type: single-phase, three-phase with neutral or three-phase without neutral.
- Confirm CT secondary: .../5 A or .../1 A.
- Confirm CT ratio, CT class, CT direction and wiring polarity.
- Confirm voltage input level and auxiliary power supply availability.
- Confirm panel cut-out, mounting depth and 96 x 96 mm format suitability.
- Confirm RS-485 cable routing, shielding, termination and Modbus address.
- Confirm baud rate, parity and stop bit settings for integration.
- Confirm whether digital inputs are required for tariff, source or status signals.
- Confirm relay output and transistor pulse output requirements.
- Test communication and measured values during commissioning before final handover.
Related Keywords
CIRCUTOR CVM-C4
CVM-C4-ITF-485-ICT2
Panel Power Analyzer
96 x 96 mm Power Meter
RS-485 Modbus RTU
Energy Metering
THD Monitoring
Relay Outputs
Digital Inputs
IoTWatt 4.0 Ready
CVM-C4 Supply, Installation and IoTWatt 4.0 Integration
Saturn Pyro supports CIRCUTOR CVM-C4 power analyzers for compact panel monitoring,
energy metering, Modbus RTU integration, SCADA / BMS / EMS connectivity and IoTWatt 4.0
digital energy audit projects in Malaysia.
Contact Us
更多 Saturn Pyro Sdn Bhd 相关资料