详情
CIRCUTOR Fixed Power Analyzer
CVM-B50-ITF Power Analyzer
The CIRCUTOR CVM-B50-ITF is a compact 96 x 96 mm panel-mounted power analyzer for energy
measurement, power quality visibility, downloadable data logging and remote monitoring.
It supports Ethernet, Wi-Fi and Modbus TCP/IP integration, making it suitable for SCADA,
BMS, EMS and IoTWatt 4.0 projects where fixed panel metering must be connected directly
into a digital monitoring platform.
Model M56910
96 x 96 mm Panel Mount
Ethernet + Wi-Fi
Modbus TCP/IP
31st Harmonic
Neutral Current
Autowiring
CVM-B50-ITF
Fixed Power Analyzer
Product Type
Fixed power analyzer, 96 x 96 mm panel mounted
Communication
Ethernet, Wi-Fi and Modbus TCP/IP
Measurement
4 channels, neutral current and harmonics
Application
Energy audits, EMS, SCADA and IoTWatt 4.0
Product Overview
The CVM-B50-ITF is designed for installations requiring more than basic energy metering.
It measures electrical variables, energy consumption, generation, voltage and current distortion,
individual harmonics up to the 31st order and neutral current.
The analyzer includes downloadable memory, an integrated web server, app-based configuration
and automatic wiring-error correction. These features help reduce commissioning time and make the
device practical for fixed monitoring at main panels, sub-panels, MCCs and energy management points.
Key positioning
CVM-B50-ITF is suitable when a compact fixed meter must provide local display, remote access,
downloadable data, harmonic visibility, neutral-current monitoring and Modbus TCP/IP integration.
Typical Monitoring Architecture
CVM-B50-ITF measures electrical parameters at the panel and sends data through Ethernet or Wi-Fi
using Modbus TCP/IP to SCADA, BMS, EMS or IoTWatt 4.0.
1. Measure
Voltage inputs, CT inputs and neutral current.
2. Analyze
kW, kWh, PF, THD, harmonics and demand.
3. Store
Downloadable memory with CSV data.
4. Communicate
Ethernet or Wi-Fi via Modbus TCP/IP.
5. Improve
SCADA, BMS, EMS and IoTWatt 4.0 analytics.
Key Features
MEM
Downloadable Memory
Stores approximately 40 days of downloadable data in CSV format for mobile or PC review.
WEB
Integrated Web Server
Supports configuration, display and start-up through web server or app without additional software.
LAN
Ethernet and Wi-Fi
Built-in Ethernet and Wi-Fi communication with Modbus TCP/IP protocol.
N
Neutral Current Measurement
Measures neutral current to detect imbalance and possible neutral conductor overload.
31
Harmonics up to 31st Order
Displays THDU%, THDI% and individual phase harmonics up to the 31st order.
AUTO
Automatic Autowiring
Automatic wiring-error correction helps simplify installation and commissioning.
4Q
Four-Quadrant Measurement
Measures both consumption and generation for modern electrical installations.
I/O
Digital Inputs and Outputs
Includes 4 digital inputs, 2 relay outputs and 2 transistor digital outputs.
LCD
User-Defined Screens
Allows selected variables and status indication for inputs, outputs and tariff.
Main Applications
CVM-B50-ITF is suitable for facilities that need compact fixed monitoring of electrical variables,
energy consumption, power quality indicators and network harmonics.
Energy Audits
Measure consumption, generation, demand, power factor and electrical variables for audit work.
ISO 50001 and EECA Support
Supports energy measurement and monitoring for energy management systems and compliance reporting.
Harmonic Monitoring
Detect THD and individual harmonics for power quality and network health reviews.
Neutral Overload Detection
Neutral current measurement supports imbalance and neutral conductor loading analysis.
SCADA / BMS / EMS
Integrate values through Modbus TCP/IP using Ethernet or Wi-Fi communication.
IoTWatt 4.0 Integration
Use as a field analyzer for dashboards, alarms, analytics, EECA reporting and digital energy audits.
Model and Main Characteristics
| Item |
CVM-B50-ITF |
| Product Code |
M56910 |
| Product Type |
Fixed power analyzer, 96 x 96 mm panel mounted |
| Protocol |
Modbus TCP/IP |
| Communications |
Ethernet and Wi-Fi |
| Memory |
Built-in downloadable memory |
| Measuring Channels |
4 |
| Input Current |
.../5 A and .../1 A current transformer inputs |
| Harmonics |
Up to 31st order |
| Digital Inputs |
4 |
| Relay Outputs |
2 |
| Transistor Outputs |
2 |
| Mounting |
Panel mounting |
Electrical Measurement and Accuracy
| Parameter |
Specification |
| Nominal Voltage |
230 V phase-neutral, 400 V phase-phase |
| Frequency Measuring Range |
50 to 60 Hz |
| Voltage Input Impedance |
400 kΩ |
| Minimum Measurement Voltage |
11.5 V phase-neutral |
| Maximum Voltage |
300 V phase-neutral / 520 V phase-phase |
| Current Input |
5 A, .../5 A or .../1 A |
| Minimum Current Measurement |
10 mA |
| Phase Voltage Accuracy |
0.2% from 20% to 120% Un |
| Phase Current Accuracy |
0.2% from 10% In to 120% In |
| Active Power Accuracy |
0.5% ± 2 digits |
| Apparent Power Accuracy |
0.5% ± 2 digits |
| Reactive Power Accuracy |
1% ± 2 digits |
Power Supply, I/O and User Interface
Power Supply
| AC Supply | 100 to 240 Vac ±10% |
| Frequency | 50 to 60 Hz |
| AC Consumption | 5 to 8 VA |
| DC Supply | 100 to 240 Vdc ±10% |
| DC Consumption | 2.7 to 3 W |
| Installation Category | CAT III 300 V |
Inputs and Outputs
| Digital Inputs | 4 NPN digital inputs, 2000 V insulation |
| Relay Outputs | 2 relay outputs, 625 VA / 75 W AC1 |
| Transistor Outputs | 2 NPN digital transistor outputs |
| Transistor Voltage | 24 Vdc maximum |
| Transistor Current | 50 mA maximum |
| Pulse Width | 30 ms to 400 ms, programmable |
User Interface
| Display | Custom COG LCD |
| LEDs | 2 LEDs |
| Keyboard | 3 keys |
| Local Display | User-defined screens and status indication |
Mechanical and Environmental
| Working Temperature | -10°C to +50°C |
| Storage Temperature | -25°C to +75°C |
| Relative Humidity | 5% to 95%, without condensation |
| Protection | IP20, front IP54 |
| Enclosure | Self-extinguishing V0 plastic |
| Dimensions | 96 x 96 x 67 mm |
| Weight | 0.363 kg |
Standards and Design Compliance
The CVM-B50-ITF is designed according to relevant measurement, safety, EMC and environmental
standards for fixed electrical measurement equipment.
IEC / EN 61010-1
IEC / EN 61010-2-030
IEC 61557-12
IEC 61326-1
UNE-EN 61000-4 Series
ETSI EN 301 489-1
ETSI EN 301 489-17
CAT III 300 V
Why Use CVM-B50-ITF?
- Combines energy metering, power analysis and harmonic visibility in one compact 96 x 96 mm panel device.
- Ethernet and Wi-Fi communication simplify integration into SCADA, BMS, EMS and IoT systems.
- Built-in web server and app configuration reduce commissioning dependency on special software.
- Autowiring correction helps reduce wiring error issues during installation.
- Neutral current measurement supports imbalance and neutral conductor overload detection.
- Digital inputs and outputs support pulse logging, tariff status, sensor status and simple automation actions.
- Built-in CSV-downloadable memory supports data review and energy audit documentation.
Integration with IoTWatt 4.0
CVM-B50-ITF can be integrated into IoTWatt 4.0 through Modbus TCP/IP using Ethernet or Wi-Fi.
It is suitable for sites where fixed panel measurement is needed for energy dashboards, digital energy
audits, EECA reporting, alarms, performance analytics and longer-term energy monitoring.
| IoTWatt 4.0 Use |
How CVM-B50-ITF Supports It |
| Energy Dashboards |
Supplies kWh, kW, voltage, current, power factor, demand and related electrical values. |
| Power Quality Visibility |
Provides THD and individual harmonics up to the 31st order. |
| Neutral Current Monitoring |
Supports imbalance and neutral loading analysis. |
| Digital Energy Audit |
Provides fixed measurement points for baseline review, load profiling and audit evidence. |
| EECA Reporting |
Supports continuous energy monitoring data for reporting and energy management review. |
| Alarm Workflow |
Digital outputs and IoTWatt alarms can be used for operating alerts and maintenance actions. |
Recommended Selection and Deployment Checklist
- Confirm required current input: .../5 A or .../1 A CTs.
- Confirm CT ratio, CT class and installation direction.
- Confirm voltage level: 230 V phase-neutral / 400 V phase-phase application.
- Confirm panel cut-out, mounting clearance and front IP54 requirement.
- Confirm communication method: Ethernet or Wi-Fi.
- Confirm Modbus TCP/IP register mapping and integration platform.
- Confirm whether digital inputs are required for pulse meters, tariff or sensor status.
- Confirm relay / transistor output requirements for alarms, pulses or automation.
- Confirm memory download and CSV data usage requirement.
- Test voltage phase sequence, CT polarity and Autowiring correction during commissioning.
CVM-B50-ITF Supply, Installation and IoTWatt 4.0 Integration
Saturn Pyro supports CIRCUTOR CVM-B50-ITF power analyzers for fixed electrical monitoring,
harmonics visibility, energy audits, SCADA / BMS / EMS integration, Modbus TCP/IP communication
and IoTWatt 4.0 digital energy audit projects in Malaysia.
Contact Us
更多 Saturn Pyro Sdn Bhd 相关资料