Fire-Rated Kitchen Exhaust Riser Installation

Fire-Rated Kitchen Exhaust Riser Installation

Danh mục: Specialized HVAC Duct Fabrication & Rigging Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại eakon.com.my

Mô tả

Fire-Rated Kitchen Exhaust Riser Installation by EKG M&E Sdn Bhd

In 2026, the installation of Fire-Rated Kitchen Exhaust Risers is one of the most critical life-safety requirements for commercial buildings. Under BOMBA (Jabatan Bomba dan Penyelamat Malaysia) regulations and MS 1472, any kitchen exhaust duct passing through multiple floors or fire compartments must be fire-rated to prevent the spread of fire and toxic grease-smoke. For high-rise assets in Kuala Lumpur and Selangor, a non-compliant riser is a primary reason for a failed annual Fire Certificate (FC) renewal.

At EKG M&E Sdn Bhd, we apply 34 years of mechanical engineering expertise to the specialized fabrication and high-altitude rigging of fire-rated systems. We ensure your exhaust path is a "Fortified Tunnel" that protects both your occupants and your building's 5-Star Energy Intensity Label under the EECA 2024.


1. The Engineering Logic of Fire Containment

A kitchen exhaust duct is uniquely dangerous because it is often coated in flammable grease. If a fire starts on the stove, the duct becomes a "Fuse" that can carry the fire to every floor of the building.


2. Specialized Fabrication & Rigging Protocol

Installing a vertical riser through a building's core requires high-precision rigging and specialized materials:

A. Pre-Fabricated Fire-Rated Ducting

We utilize specialized ductwork that is factory-coated with fire-resistant intumescent spray or wrapped in high-density mineral wool with an aesthetic outer cladding.

B. The "Vertical Lift" Rigging Plan

Rigging a 10-story riser requires a detailed "Lifting Plan." We use specialized winches and hoisting equipment to position duct sections within the vertical shaft. Every section is secured with Fire-Rated Support Brackets designed to withstand the duct's massive dead weight.

C. Fire-Stopping and Compartmentation

The point where the duct passes through the concrete floor is the most vulnerable. We install Fire-Stop Collars and specialized fire-rated sealants to ensure the floor's fire integrity is perfectly restored after the duct is rigged.


3. Compliance Matrix: Audit-Ready Safety Data

Our installation reports provide the "Physical Truth" required for your Professional Engineer (PE) and BOMBA:

Requirement BOMBA / MS 1472 Standard EKG Certified Performance
Fire Rating 2 to 4 Hours (as per UBBL) Certified & Labelled
Leakage Class High Pressure (Grease-Tight) Verified DW143 Class C
Clean-Out Access Every 3 Meters / Each Bend Fitted & Accessible
Rigging Safety Certified Lifting Plan Fully Documented
EECA Status Airtight Path Audit-Ready for 5-Star BEI

4. Why Professional Riser Installation is Essential for 2026

Why Choose EKG M&E Sdn Bhd?

Is your kitchen's fire-safety path a certified barrier or a hidden liability? Contact EKG M&E Sdn Bhd today for specialized fire-rated kitchen exhaust riser installation and secure the safety and compliance of your building.

Xem thêm chi tiết về EKG M & E SDN BHD